Project errors come in all shapes and sizes, so let’s look at a few common ones. A key question to ask is does this affect all my Projects or just one of them.
Affects All:
My Project looks different:
You are in Scriptwriting Mode:
You could have accidentally hit the Keyboard shortcut CTRL + 8 which will place you in Screen writing mode.
You can see below the four signs you are in Scripting mode.
#1. Current Binder item’s text icon is yellow.
#2. The Icon in the Editor top bar is also yellow.
#3. The footer is missing the file’s word count.
#4. You have a new option menu in the lower right of the Editor footer. (See below)
The Event Log- Use for a single project or a problem affecting all of them.
How can I identify the problem to ask for help?
Scrivener has a built-in internal event log which can give insight into errors and help solve them.
To View this-
1. Use the Menu command File > Options > Warnings (this is new in version 3.16)
2. Check the box in the Options panel to use this function.
3. Restart Scrivener.
This file provides information to Scrivener’s Technical support.
You can take an image of the error message or click inside the window of text and hit Ctrl + A to select all and then Copy and paste into a text program and send to L&L.
Your Issue: A single Project with blank files
The folders and Documents are in the Binder but the text is gone.
There are several possible culprits:
A.) Synchronization Issues- Blank documents are a classic sign of a synchronization issue. Only Dropbox is recommended by Scrivener for hosting Scrivener Project Folders. Doing this with other services such as OneDrive, Google Drive, iCloud Drive can all cause issues due to synchronization issues. However, all of these can safely host zip backups of your projects. Make sure these services are set up to host your files BOTH online and offline on the computer. Look for your last Project backup and open this to recapture files.
***Windows automatically installs OneDrive, which may be backing up the folder where you are saving Scrivener Projects. Incomplete synchronization without fully local files can cause this. To Fix move the Project folder, or change the settings to exclude Your Project Folder from OneDrive. This can happen with other backup services as well. Make sure Scrivener files are set to be saved locally.
B.) Security/Antivirus Software- You may need to temporarily turn off your security and Antivirus software to see if this is an issue and then change permissions to allow Scrivener to properly function, if it is.
Steps to do this for Windows Window Defender (but these are similar for other products) include:
Go to Windows Settings via the Start button and select “Update & Security.”
Select “Windows Security”
Click “Virus & threat protection”
Scroll the window until you see “Exclusions” then click “Add or remove exclusions”
Click the “Add an exclusion” button and add the folder of your Scrivener project(s)
An example with Bitdefender’s Antivirus-
C.) Read/Write permissions are incorrect- Look at the permissions for the Scrivener Project folder and its sub-folders. Make sure Authenticated Users and Users have full control.
1. Right-click on the Project folder.
2. Select the last option of Properties
3. Click the Security tab.
If you need to change permissions, then click the Edit button.
What the settings mean?
Common NTFS permission levels
Read: view file data and basic attributes.
Read & execute (RX): read data and run executable content; on a folder this commonly includes List folder contents.
List folder contents: see the names of items in a folder. It is a folder-oriented permission and is separate from the ability to change file data.
Write: create or write data and attributes where the rest of the ACL permits it.
Modify: read, write, create, and delete content without granting the ability to change permissions or ownership.
Full control: includes Modify plus changing permissions and taking ownership. Reserve it for administrators or trusted service identities that genuinely require it.
Apply your choices to the Project folder
After done then click ok.
Now check to make sure your text is visible.
Consider closing Scrivener if inactive for too long.
It is also recommended to set up the option to automatically close your Scrivener program after a certain period of inactivity, which if set up properly will trigger an automatic backup. This option for an automatic close is found in Options > General Startup. The automatic quit time can be up to 300 minutes. This will close the project if you walk away and forget to. By closing the program, you protect yourself against data loss with power failures, or accidental computer closure.
***
REMEMBER:
It is crucial to regularly backup projects as zip backups and save them by more than one method. Do this daily when actively writing. Consider the Options in the Backup tab of the Backup panel where you can choose crucial options such as to backup on project close (recommended) and do compressed (zip) backups (recommended).
This next problem usually affects a Single Project, but can affect all of them.
A Scrivener Project will not open
If the Scrivener Project will not open at all/ or is corrupted. Try these methods:
1. Try to clear your Interface Settings and restore the default settings.
This can often be the problem. To reach this option from inside Scrivener, you must hold the ALT key before clicking the Menu command File to see a new menu option of File > Close Project and Clear Interface Settings. This will restore the default Scrivener options. This is why regular backups of Scrivener are crucial when you write or rewrite inside a Scrivener Project.
Manually Resetting the Interface if a Project Will Not Open
If a project will not open at all, then you'll need to reset the user interface file manually. This isn't hard to do, but you should have been creating regular backups first, since you'll manipulate files in your Scrivener Project. Personally, I have not lost any project data doing this.
Backup one of two ways:
A. Use the Menu command File > Backup Now and create a backup of the Project before doing the steps below. Obviously, this will not be an option if the Project will not open. But you should use this option regularly if you do not have automatic backup options set to occur when your program closes. (Recommended)
B. Locate the specific Scrivener Project folder on your computer and right-click on it. Look for the Send to option and choose Compressed (zipped) folder option which will compress the Project into a ZIP file. This will be your backup copy, so keep it safe. (Place this on an external drive, desktop, or a cloud drive folder.)
With your Project backed up, use the Menu command File > Show Project in File Explorer to find the (Scrivener) Project Folder with the Project you want to open. (Do this if the problem/error only involves one Project.)
Scrivener Tip: Designate one folder to hold all of your Scrivener Projects, so you always remember where they are stored. I used the uninspiring name of Scrivener Project Folder on my main drive.
Now open the specific Scrivener Project and then open the Settings folder and find and delete the "ui.ini" and "ui-common.xml" files.
Now back up a level and right-click on the scrivx file for the Scrivener Project, choose the top option of open and see if the problematic Project will now open in Scrivener.
The deleted files in step one are freshly recreated. If the recreated project is intact, discard the compressed backup you made.
Note: If you have problems with the Project Search Interface locking up in one mode, using the method above may reset the interface for the Project. If this fails, consider moving the documents and metadata to a new blank Project.
2. You can also use the option of Save and Rebuild Search Indexes.
This will make sure Scrivener cleans up the Search Indexes, which help it find files in the Project. Use the Menu command File > Save and Rebuild Search Indexes.
3. Restore your project from a backup.
A. Rename the broken Scrivener Project folder. (Like Original Project name and add broken.)
B. Restore the problematic Project from its most recent zip backup.
C. Use the Project Search option of modified date to search for recently opened files. Choose something like mdate:>7d to find all recently modified/created files from the past week. Save this as a collection.
D. Now use the Menu command File > Import > Scrivener Project which imports the broken project into the currently open project at the bottom of the Binder. Look first at the most recently modified files in the newly created collection to look for changes. Also, look for any newly created files as well.
E. You could also start with a new blank project and then import the damaged project which may reconstruct it.
F. Delete the imported project when you are done.
Note:
By default, Scrivener backups are located...
On Windows: C:\Users\[UserName]\AppData\Local\LiteratureAndLatte\Scrivener\Backups
On macOS: [Home folder]/Library/Application Support/Scrivener/Backups.
If you’ve changed the default backup location, you can find the backup folder location in Scrivener’s settings. I personally change the folder location to a cloud drive for my zip backups. This allows me flexibility when working from more than one location. Use the Menu command File > Options > Backup > Backup location. Now click the Choose button to change the default Backup location. The Windows Explorer opens with the current location and you can now change it. You can leave the previously created backups where they are or move them into your new location choice. (I would strongly recommend having all backups in the same folder.)
#1. This is the current location of your backup files (They can be compressed which is the recommended form or noncompressed folders).
#2. Click Choose to change the location of backups going forward.
#3. Directly opens the backup folder in the Windows Explorer.
4. When you are happy with the changes in your backup location, then hit apply.
***
When using the Menu command File > Import > Scrivener Project
Scrivener attempts to import any corrupted projects which do not open normally any more, as best as possible.
Scrivener will import the Project, reconstruct the Binder structure, and add a Root folder with the imported Project's name at the bottom of the Binder.
Drag the content of the imported Project into the Draft or Research folder.
Check to see if the imported Project is complete.
Scrivener will make every attempt to restore the outline structure and import the raw data. From there, you can make the best possible attempt at repairing the project.
***
Problem- Your Project is slow to respond:
The first question to ask is this a single project, or all of them? Each situation will have different causes and solutions.
Project Bloat: An excessive number of images can bloat and slow Scrivener. Consider while writing to import images, videos, webpages, etc as Research file shortcuts. Use the Menu command File > Import >Research Files as Shortcuts. This method will give you access to the media, without substantially increasing the Scrivener Project size.
Adjusting your Mouse cursor settings: I found when I added a Text cursor indicator which could be colored and have various animations this dramatically slowed Scrivener.
Sometimes a simple restart of the computer will correct sluggish performance problems with Scrivener.
Problem - Slow Backups
If the backup times for your project stretch out, look at the size of the project and where you are storing it. If you are storing it on a small external drive which is nearly full this can cause slower backup times. The solution is find a larger place to backup, or reduce the project size by using File shortcuts to large research files. Using the Menu command File > Import > Research Files as Shortcuts will have a shortcut to the file placed in your project, but it will behave like a regular file, but without changing the project size.
Slow Typing in Scrivener
This issue needs its own separate discussion and is covered in another blog on this website. Check Here
Template Reading Error:
When I open one of my Scrivener projects, this error message pops up: “Errors reading project. Error reading template info: Line:1 Column:0 Error:1” I’m still able to edit the project after dismissing the notification, but I’m wondering if there’s a way to fix whatever I’ve done so that it stops popping up.
This can occur if the template metadata file is damaged.
Do this:
1. Navigate to Scrivener Project Folder.
2. Open the project folder and then the settings folder. Cut and paste the templateinfo.xml file to the desktop (ie another location)
3. Now click on the scrivx file to open this project in Scrivener. Scrivener will recreate this file. If the error message disappears, then nothing else needs to be done.
***
Project not in recommended save location. (Pop up Error message)
A Popup Error message says the Project (is) not in a recommended save location.
This means that your backup folder is saving backups into the same location where your project folders are stored. This is generally not a good idea.
You need to change your backup location. To do this, go to the Menu command File > Options > Backup
#1. This is the current location of your backup files (compressed which is the recommended form or noncompressed).
#2. Click Choose to change the location of backups going forward.
#3. Directly opens the backup folder in the Windows Explorer.
#4. When you are happy with the changes in your backup location, then hit apply.